Coriolis meter manufacturer 2025

Premium coriolis mass flow meter factory: A mass flow meter may require more frequent maintenance, such as cleaning and calibration, than a magnetic flow meter. A magnetic flow meter, on the other hand, requires relatively little maintenance, because it has no moving parts and is not affected by wear and tear. Measurement Principle: As mentioned above, mass flow meters measure the mass of the fluid in order to determine the flow rate. While magnetic flow meters use magnetic fields to measure the flow of conductive fluids. Read even more info on turbine flow meter manufacturer.

Flow measurement of some low-viscosity oils, such as gasoline, kerosene, diesel, and heavy oil, residual oil, etc. whose viscosity is reduced by heating. Water flow measurement of large-diameter pipelines, among which the full-tube vortex flowmeter is mainly used for small and medium diameter pipes, while the insertion vortex flowmeter can be used for large-diameter (DN≥300mm) pipeline flow measurement. It is widely used in urban water pipelines and industrial water mains in chemical, electric power, metallurgy, papermaking, chemical fiber and other enterprises.

Gas turbine flow meter is a kind of instrument and equipment used to measure gas measurement. Since it was developed in the domestic market, you will find that the sales in many gas distribution stations, gas companies, gas plants and other places across the country are increasing. So what are the specific market advantages? The pressure loss of the gas turbine flowmeter instrument is small, and the impeller configured on it has a very strong anti-corrosion function, so that the usability of the instrument and equipment will become stronger and stronger. When it is sold in the national market , found that the function of its flowmeter instrument is getting more and more perfect. When the instrument and equipment are promoted in the market, it has become a new generation of gas measurement equipment, creating a technologically dominant position and making customers feel that its function will be more perfect. of.

Beijing Sincerity Automatic Equipment Co., Ltd is a research and development center, focusing only on one type of flow meter, the Coriolis mass flow meter, which has been in use for 33 years. Our Coriolis mass flow has reached the international leading level. We provide three types of Coriolis mass flowmeters, including U-shaped, micro-bent V-shaped and triangular, to meet the different needs of different industries. We can provide coriolis flow meter with ultra high pressure of 100MPa, ultra high temperature of 350 C, and minimum temperature of -300 C. We can also measure ultra-high viscosity liquids, such as 70,000 cps glue. We have been very successful with gas measurements such as hydrogen. In addition, we have been very successful in two-phase / three-phase / multiphase flow liquid measurement. We support OEM services. You can even customize the internal software for Coriolis mass flow meters. We also support market agents. Discover even more information at https://www.bjssae.com/.

Beijing Sincerity has developed over years to manufacture the Coriolis Mass Flow Meters industries. Through continuous research, development and transformation, we have become the leader of the Coriolis Mass Flow Meters industries in China. The Coriolis measuring principle is used in a wide range of different branches of industry, such as the life sciences, chemicals, petrochemicals, oil and gas, food, and – no less importantly – in custody transfer applications. Coriolis flowmeters can measure virtually all fluids: cleaning agents, solvents, fuels, crude oil, vegetable oils, animal fats, latex, silicon oils, alcohol, fruit solutions, toothpaste, vinegar, ketchup, mayonnaise, gases or liquefied gases.

It has been considered in the design that the steam becomes superheated, or it is difficult to determine which state it is in, or sometimes it is superheated and sometimes saturated, so the temperature and pressure compensation is adopted, and the above phase change has no effect on the measurement results. Considering saturated steam in the design, and adopting pressure compensation, the above-mentioned phase change will bring about a small error, that is, the compensation error caused by the density difference corresponding to the difference between the superheated steam temperature and the saturated steam temperature. The design is based on saturated steam, but temperature compensation is used, that is, the temperature of superheated steam is used as the saturation temperature to check the density table, which will generally cause large errors.

American first unit of coriolis mass flow meter entered China SINCE 1987. Beijing Sincerity belongs to the state owned enterprise, which is Beijing institute of chemical industry, SINOPEC automation instrument department. SINOPEC has invested large amount of money to ask Beijing Sincerity to develop the VERY FIRST Chinese domestic coriolis mass flow meter since 1987. Chinese very first unit of U shape coriolis mass flow meter was successfully developed by Beijing Sincerity Group. Beijing Sincerity won the National Science and Technology progress awards. – SINCER 1989.